Safety-Reports Administrator Dashboard Examples

Inspections Training JSA Observations Incidents Scan Forms

01/24/2025 - 01/23/2026
Inspection Dashboard Sample
Total
Inspections
583
TREND 
97%
Positive
Observations
3,383
TREND 
35%
Negative
Observations
1,333
TREND 
14%
Total
Observations
4,716
TREND 
28%
Observations


Report Score:72%
# Inspections vs Report Score
 
Top 5 Categories (Of Issues)

~
Top 10 Negative Observations

~
Sub-CategoryCount
1AsbestosEmployer does not/cannot assure that employees are not exposed to more than 0.1 fibers per cubic centimeter of air for an 8 hour TWA (1926.1101)48
2Concrete/MasonryRebar is not adequately guarded to eliminate impalement hazard (reference 1926.701)26
3Electrical SafetyCord sets and/or Power Supply cords are "daisy chained" (1926.403)21
4BehaviorsWorkers observed not keeping eyes on path (i.e. did not look in direction of travel)20
5Electrical SafetyGFCI is not used on all temporary power connections (1926.404)19
6Electrical SafetyElectrical equipment not installed/used as listed or labeled (1926.403)19
7AsbestosAll workers are not adequately informed of the existence (i.e. regulated areas) and/or requirements of asbestos on multi-employer worksites (1926.110116
8BehaviorsWorkers observed not looking back prior to stepping backwards14
9AsbestosEmployees may be exposed to the excursion limit of more than 1.0 fibers per cubic centimeter of air for as averaged over 30 min. sampling period (192613
10Aisles/WalkwaysNot all aisles and walkways are kept clean and orderly (1910.22)13
1Electrical SafetyElectrical equipment installed/used as listed or labeled (1926.403)76
2Electrical SafetyGround pins are attached to electrical cords (i.e. extension cords and/or flexible cord sets) (1926.404)73
3Electrical SafetyGFCI is used for temporary power connections (1926.404)60
4Fall ProtectionSuitable fall protection is provided and used at unprotected sides/edges when working 6 feet or more above lower level (1926.501)54
5Fall ProtectionWorkers utilize PFA system when working near unprotected sides/edges 6 feet or more above lower level or under 6 feet if policy dictates (1926.501)42
6Electrical SafetyElectrical equipment is free from recognized hazards and maintained in good working order as intended by the manufacturer (1910.303)41
7Fall ProtectionSteps have been taken (i.e. barricades, covers, warning lines, etc.) and are adequate to protect workers from falling through holes, skylights, roof h40
8Electrical SafetyCord sets and/or Power Supply cords are used per Listing (i.e. not interconnected or "daisy chained") (1926.403)37
9Electrical SafetyFlexible cords are maintained in good condition (1926.416)37
10Electrical SafetyElectrical equipment is installed/used as listed or per manufacturer specifications (1910.303)36
Inspections by Company
Average Score by Company
Inspections by Inspector
Average Score by Inspector
eCAT Dashboard
Use this dashboard To analyze your Corrective Action Tracking.
   
84%
Open
   
0%
Pending
   
16%
Closed
Average Days
Open
177
Average Days
to Close
6
Average Days Open - All open/closed/pending items are included in this count.
Average Days to Close - Only "Closed" action items are included in this count
01/24/2025 - 01/23/2026

Open:1,070
Pending: 3
Closed: 204
01/24/2025 - 01/23/2026
OpenPendingClosed% Closed
JAN 202690325%
DEC 2025260824%
NOV 20252901128%
OCT 20256721619%
SEP 20257401618%
AUG 202525803713%
JUL 20258202423%
JUN 202510701714%
MAY 202513411611%
APR 20258502120%
MAR 20258801414%
FEB 20259901715%
JAN 2025120425%