Safety-Reports Administrator Dashboard Examples

Inspections Training JSA Observations Incidents Scan Forms

07/13/2024 - 07/12/2025
Inspection Dashboard Sample
Total
Inspections
494
TREND 
38%
Positive
Observations
3,613
TREND 
30%
Negative
Observations
1,596
TREND 
119%
Total
Observations
5,209
TREND 
49%
Observations


Report Score:69%
# Inspections vs Report Score
 
Top 5 Categories (Of Issues)

~
Top 10 Negative Observations

~
Sub-CategoryCount
1AsbestosEmployer does not/cannot assure that employees are not exposed to more than 0.1 fibers per cubic centimeter of air for an 8 hour TWA (1926.1101)42
2BehaviorsWorkers observed not keeping eyes on path (i.e. did not look in direction of travel)19
3Electrical SafetyCord sets and/or Power Supply cords are "daisy chained" (1926.403)16
4AsbestosEmployees may be exposed to the excursion limit of more than 1.0 fibers per cubic centimeter of air for as averaged over 30 min. sampling period (192616
5Electrical SafetyGFCI is not used on all temporary power connections (1926.404)14
6Concrete/MasonryRebar is not adequately guarded to eliminate impalement hazard (reference 1926.701)14
7BehaviorsWorkers observed not looking back prior to stepping backwards14
8AsbestosAll workers are not adequately informed of the existence (i.e. regulated areas) and/or requirements of asbestos on multi-employer worksites (1926.110114
9Concrete/MasonryHandles on concrete buggy extend beyond wheel width (1926.702)13
10Confined SpaceSite has hazards requiring a determination for Permit-Required Confined Spaces, and plan or precautions are not in place, or inadequate for these spac12
1Electrical SafetyElectrical equipment installed/used as listed or labeled (1926.403)59
2Electrical SafetyGround pins are attached to electrical cords (i.e. extension cords and/or flexible cord sets) (1926.404)51
3Electrical SafetyGFCI is used for temporary power connections (1926.404)43
4Fall ProtectionSuitable fall protection is provided and used at unprotected sides/edges when working 6 feet or more above lower level (1926.501)36
5Concrete/MasonryRebar is guarded to eliminate impalement hazard (reference 1926.701)34
6AsbestosEmployer assures that employees are not exposed to more than 0.1 fibers per cubic centimeter of air for an 8 hour TWA (1926.1101)34
7Electrical SafetyCord sets and/or Power Supply cords are used per Listing (i.e. not interconnected or "daisy chained") (1926.403)32
8Confined SpaceThe worksite is evaluated and permit spaces are identified with signage (1926.1203)29
9Fall ProtectionSteps have been taken (i.e. barricades, covers, warning lines, etc.) and are adequate to protect workers from falling through holes, skylights, roof h28
10Electrical SafetyFlexible cords are maintained in good condition (1926.416)26
Inspections by Company
Average Score by Company
Inspections by Inspector
Average Score by Inspector
eCAT Dashboard
Use this dashboard To analyze your Corrective Action Tracking.
   
91%
Open
   
0%
Pending
   
9%
Closed
Average Days
Open
189
Average Days
to Close
0
Average Days Open - All open/closed/pending items are included in this count.
Average Days to Close - Only "Closed" action items are included in this count
07/13/2024 - 07/12/2025

Open:1,347
Pending: 3
Closed: 136
07/13/2024 - 07/12/2025
OpenPendingClosed% Closed
JUL 2025100844%
JUN 20259601514%
MAY 202513111510%
APR 20258601817%
MAR 20258801414%
FEB 20259901715%
JAN 20255401016%
DEC 202412018%
NOV 2024210313%
OCT 20241060119%
SEP 2024596061%
AUG 20242721433%
JUL 2024210416%