Safety-Reports Administrator Dashboard Examples
Inspections
Training
JSA
Observations
Incidents
Scan
Forms
Last 7 Days
Last 30 Days
Last 12 Months
03/29/2022 - 03/28/2023
Inspection Dashboard Sample
Total
Inspections
670
TREND
21%
Positive
Observations
8,228
TREND
26%
Negative
Observations
2,479
TREND
23%
Total
Observations
10,707
TREND
25%
Observations
Report Score:
77%
# Inspections vs Report Score
--All Checklist--
Best Practice Audit
Construction - 1926
Construction - CalOSHA
Construction - WISHA
COVID-19 Checklist
COVID-19 Checklist (CalOSHA)
COVID-19 Healthcare ETS - CalOSHA
COVID-19 Healthcare ETS - Federal
DOT-FMCSA - 49 CFR
Ergonomics - Industrial
Ergonomics - Office
Gen. Ind. - CalOSHA
General Ind. - 1910
Incident Report
Long Term Care Facility CMS Checklist
MSHA - Surface Mining
Office Safety - Federal
USACE EM 385
Top 5 Categories (Of Issues)
~
Top 10 Negative Observations
Sub-Category
Count
1
Asbestos
Employer does not/cannot assure that employees are not exposed to more than 0.1 fibers per cubic centimeter of air for an 8 hour TWA (1926.1101)
56
2
Behaviors
Workers observed not keeping eyes on path (i.e. did not look in direction of travel)
37
3
Concrete/Masonry
Rebar is not adequately guarded to eliminate impalement hazard (reference 1926.701)
29
4
Electrical Safety
Ground pins are not attached to all electrical cords (i.e. extension cords and/or flexible cord sets) (1926.404)
29
5
Electrical Safety
Cord sets and/or Power Supply cords are "daisy chained" (1926.403)
22
6
Asbestos
Employees may be exposed to the excursion limit of more than 1.0 fibers per cubic centimeter of air for as averaged over 30 min. sampling period (1926
21
7
Fire Safety
Fire extinguisher not provided on each floor (1926.150)
21
8
Electrical Safety
Lamps used for general illumination not protected from accidental contact/breakage (1926.405)
20
9
Electrical Safety
Electrical equipment not installed/used as listed or labeled (1926.403)
20
10
Electrical Safety
All sockets in temporary lighting do not have bulbs (1926.416)
19
~
1
Electrical Safety
Electrical equipment installed/used as listed or labeled (1926.403)
84
2
Electrical Safety
Ground pins are attached to electrical cords (i.e. extension cords and/or flexible cord sets) (1926.404)
53
3
Electrical Safety
GFCI is used for temporary power connections (1926.404)
51
4
Electrical Safety
Cord sets and/or Power Supply cords are used per Listing (i.e. not interconnected or "daisy chained") (1926.403)
50
5
Fire Safety
Fire extinguishers are maintained in operating condition (1926.150)
49
6
Asbestos
Employer assures that employees are not exposed to more than 0.1 fibers per cubic centimeter of air for an 8 hour TWA (1926.1101)
47
7
Fire Safety
Portable fire extinguishers are inspected periodically (i.e. monthly) (1926.150)
45
8
Ladders/Stairs
Ladders are inspected/no visible defects (1926.1053)
43
9
Electrical Safety
Flexible cords are maintained in good condition (1926.416)
42
10
Fire Safety
Portable fire extinguishers are maintained annually 1926.150(c)(1)(viii)
39
Inspections by Company
Average Score by Company
Inspections by Inspector
Average Score by Inspector
eCAT Dashboard
Use this dashboard To analyze your Corrective Action Tracking.
69%
Open
1%
Pending
30%
Closed
Average Days
Open
123
Average Days
to Close
16
Average Days Open
- All open/closed/pending items are included in this count.
Average Days to Close
- Only "Closed" action items are included in this count
03/29/2022 - 03/28/2023
Open:
1,503
Pending:
21
Closed:
657
03/29/2022 - 03/28/2023
Open
Pending
Closed
% Closed
MAR 2023
137
4
45
24%
FEB 2023
92
5
47
33%
JAN 2023
118
1
52
30%
DEC 2022
441
0
39
8%
NOV 2022
42
0
29
41%
OCT 2022
48
1
36
42%
SEP 2022
77
0
38
33%
AUG 2022
86
1
76
47%
JUL 2022
87
1
44
33%
JUN 2022
109
0
43
28%
MAY 2022
136
4
111
44%
APR 2022
114
4
89
43%
MAR 2022
16
0
8
33%